SPARC S7-2
Processor | |||||||||||||
Number | One or two SPARC S7 8-Core, 4.27GHz processors, not expandable | ||||||||||||
CPUs |
|
||||||||||||
Cache memory | Level 1:16KB instruction and 16KB data per core Level 2:256KB L2 I$ per four cores, 256KB L2 D$ per core pair Level 3:16MB L3$ on chip |
||||||||||||
Main Memory | |||||||||||||
Capacities |
|
||||||||||||
Standard Integrated Interfaces | |||||||||||||
Network | 4 × 10 GbE Ethernet ports (100 Mbps/1 Gbps/10 Gbps), full duplex only, auto-negotiating | ||||||||||||
Network Management | One dedicated 10Mbps/100Mbps/1Gbps RJ-45 port Ethernet port | ||||||||||||
Serial Management | One dedicated RJ-45 port | ||||||||||||
Remote Management | Integrated Lights Out Manager (ILOM) | ||||||||||||
USB | Two USB 2.0 ports (front) | ||||||||||||
PCI Expansion Slots |
|
||||||||||||
Internal Mass Storage | |||||||||||||
Disks |
|
||||||||||||
Power Supplies | |||||||||||||
2 × 800 or 1200 Watt, hot-swappable, N+1 redundant power supply units (PSU) | |||||||||||||
Environment | |||||||||||||
Input Voltage | 100 to 120 VAC at 800W, 50/60Hz 200 to 240 VAC at 1200W, 50-60Hz |
||||||||||||
Input Current | 4.1/8.6 A @ 100/200 VAC (max) | ||||||||||||
Input Power | 851/819W @ 100/200 VAC (max) | ||||||||||||
Maximum Heat Dissipation | 2904 BTU/hr, 3064 KJ/hr | ||||||||||||
Power Consumption | Online power calculator | ||||||||||||
Temperature |
Operating:5° C to 35° C (41° F to 95° F) ; decrease in maximum temperature: above 900 M (2952 ft) 1° C/300 m (1.8°/984 ft) |
||||||||||||
Humidity | Operating:10% to 90% relative humidity noncondensing, 27° C (81° F) maximum dew point Nonoperating:93% relative humidity noncondensing, 38° C (100° F) maximum wet bulb |
||||||||||||
Altitude |
Operating:0m to 3,000m (0 ft. to 9,840 ft), except in China markets where regulations may limit installations to a maximum altitude of 2000 m |
||||||||||||
Acoustic Noise - Sound Power Level LwAD | 60% Fan Speed:7.7 B (1 B = 10 dB) 100% Fan Speed:8.6 B (1 B = 10 dB) |
||||||||||||
Acoustic Noise - Sound Pressure LpAM | 60% Fan Speed:62 dBA (avg of four bystander positions) 100% Fan Speed:72 dBA (avg of four bystander positions) |
||||||||||||
Regulations Meets or exceeds the following requirements: |
|||||||||||||
Safety | UL/CSA 60950-1, EN 60950-1, IEC 60950-1 CB Scheme with all country differences | ||||||||||||
EMI/EMC | FCC 47 CFR 15, ICES-003, EN 55022, EN61000-3-2, EN61000-3-3 | ||||||||||||
Immunity | EN 55024 | ||||||||||||
Certifications | North American Safety (NRTL), European Union (EU), International CB Scheme, BIS (India), BSMI (Taiwan), RCM (Australia), CCC (PRC), MSIP (Korea), VCCI (Japan), VNTA (Vietnam), Morocco, Republic of Srpska. | ||||||||||||
European Union Directives | Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, and WEEE Directive 2012/19/EU | ||||||||||||
Dimensions and Weight | |||||||||||||
Height | 43mm (1.7 in.), 1U | ||||||||||||
Width | 437mm (17.2 in.) | ||||||||||||
Depth | 737mm (29 in.) | ||||||||||||
Weight | 18kg (40 lbs) max, without rackmount kit | ||||||||||||
Clearance and Service Access | |||||||||||||
Front | 1232mm (48.5 in.) | ||||||||||||
Rear | 914.4mm (36 in.) |