SPARC T7-4
Processor | |
Number | Two or Four SPARC M7 32-Core 4.133GHz processors |
Architecture | SPARC V9 architecture, ECC protected |
CPUs |
|
Main Memory | |
Capacities |
|
Standard Integrated Interfaces | |
Network | 4 × 10 GbE 100Mbps/1Gbps/10Gbps ports, full duplex only, auto-negotiating (rear) |
Network Management | One dedicated 10/100Base-T NET MGT port (rear) Note:This port does not support connections to Gigabit networks. |
Serial Management | Two RJ-45 SER MGT ports (1 front, 1 rear) |
Remote Management | Onboard system processor, running Oracle Integrated Lights Out Manager (ILOM) |
Graphics | Two high-density DB-15 video ports (1 front, 1 rear) |
USB | Front:2 USB 3.0 Ports Rear:2 USB 3.0 Ports Internal:1 USB 2.0 Port |
PCI Expansion Slots | 16 low-profile PCI-Express 3.0 slots (eight x8 & eight x16) accessed via a PCIe hot-plug carrier |
Internal Mass Storage | |
Disks |
|
Power Supplies | |
4 × 3,000 Watt, hot-swappable, 2+2 redundant power supply units (PSU) | |
Environment | |
Power Consumption | Online power calculator |
Voltage | 200 to 240 VAC |
Frequency | 50 to 60Hz |
Maximum operating input current at 200 VAC | 22.9A (16A per cord) (Actual amperage draw may exceed rating by no more than 10%) |
Maximum operating input power at 200 VAC | 4,498W (Actual power draw may exceed rating by no more than 10%) |
Temperature |
Operating:5° C to 35° C (41° F to 95° F) Note:Decrease in maximum temperature: above 900 m (2,952 ft.) 1° C/300 m (1.8° F/984 ft.) |
Humidity | Operating:10% to 90% relative humidity noncondensing, 27° C (81° F) wet bulb Nonoperating:93% relative humidity, noncondensing, 38° C (100° F) wet bulb |
Altitude | Operating:0m to 3000m (9,840 ft.) except in China markets where regulations may limit installations to a maximum altitude of 2,000 m Nonoperating:0m to 12000m (39,370 ft.) |
Acoustic Noise | Operating at peak power:9.4 B (LwAd, 1B = 10dB) Operating/Idling:79.7dB (LpAm, bystander positions) |
Regulations Meets or exceeds the following requirements: |
|
Safety | UL/CSA 60950-1 (2nd Ed), EN 60950-1(2nd Ed), IEC 60950-1(2nd Ed) CB Scheme with all country deviations, CNS 14336-1 |
EMI/EMC | FCC 47 CFR 15, ICES-003, EN55022, EN61000-3-2, EN61000-3-3 |
Immunity | EN 55024 |
Regulatory Markings | North America Safety (NRTL), European Union (EU), International CB Scheme, BIS (India), BSMI (Taiwan), RCM (Australia), MSIP (Korea), VCCI (Japan) |
European Union Directives | Restriction of Hazardous Substances (RoHS) Directive 2011/65/EU, Low Voltage Directive 2014/35/EU, EMC Directive 2014/30/EU, and 2002/96/EC Waste Electrical and Electronic Equipment (WEEE) Directive, 2012/19/EU |
Dimensions and Weight | |
Height | 215mm (8.5 in.) 5RU |
Width | 445mm (17.5 in.) |
Depth | 835mm (32.9 in.) |
Weight (approximations) | Fully Populated:Appx 89.6kg (197 lbs) (Includes two processor modules, 64 DIMMs, 8 disk drives, 16 PCIe cards, does not include rackmount kit or system packaging) Half Populated:Appx 83.5kg (184.1 lbs) (Includes one processor module, one processor filler module, 32 DIMMs, 8 disk drives, 16 PCIe cards, does not include rackmount kit or system packaging). |
Clearance and Service Access | |
Front | 914.4mm (36 in.) |
Rear | 914.4mm (36 in.) |