Oracle Server X8-2
Processor | |||||||||||||||||||||
Number | 1 or 2 Processors | ||||||||||||||||||||
CPUs | Intel Xeon Platinum 8260: 2.4GHz, 24-core, 165 watts, XCC, 35.75MB L3 cache Intel Xeon Gold 5218: 2.3GHz, 16-core, 125 watts, XCC, 22MB L3 cache Intel Xeon Gold 5222 : 3.8GHz, 4-core, 105 watts, XCC, 16.50MB L3 cache |
||||||||||||||||||||
Main Memory | |||||||||||||||||||||
Capacities |
|
||||||||||||||||||||
Standard I /O | |||||||||||||||||||||
Network | Two 10GbE RJ45 Ports or Two 10/25GbE SFP28 Ports, and One 10/100/1000BASE-T RJ45 GbE Port | ||||||||||||||||||||
Network Management | One 10/100/1000 M Base-T Network Management (NET MGT/RJ-45 connector) port | ||||||||||||||||||||
Serial Management | One serial console (SER MGT/RJ-45 connector) port. | ||||||||||||||||||||
USB | Rear:1 USB 3.0 Ports Internal:1 USB 3.0 Ports |
||||||||||||||||||||
I /O Expansion | Four PCIe 3.0 slots: three external and one internal. The internal slot supports a required internal SAS controller HBA card. PCIe slot 1 is nonfunctional in single-processor systems.
|
||||||||||||||||||||
Internal Mass Storage | |||||||||||||||||||||
Disks | Eight front-accessible and hot-swappable 2.5" disk bays. Up to 8 SAS3 HDDs/SSDs, or up to 8 NVMe SSDs, 2 internal SATA M.2 flash SSDs.
|
||||||||||||||||||||
Power Supplies and Fans | |||||||||||||||||||||
Power Supplies |
|
||||||||||||||||||||
Cooling Fans |
|
||||||||||||||||||||
Environment | |||||||||||||||||||||
Power Consumption | Online power calculator | ||||||||||||||||||||
Voltage (nominal) | 100 - 240 VAC | ||||||||||||||||||||
Input Current (maximum) | 7.2A @ 100-127VAC; 3.4A @ 200-240 VAC | ||||||||||||||||||||
Frequency (nominal) | 50/60Hz (47 to 63Hz range) | ||||||||||||||||||||
Heat Output | 11,600 BTU/hr | ||||||||||||||||||||
Temperature | Operating:5° C to 35° C (41° F to 95° F), Optimal 21° C to 33° C (69.8° F to 73.4° F) Nonoperating:-40° C to 70° C (-40° F to 158°F) Note: Maximum ambient operating temperature is derated by 1 degree C per 300 meters of elevation beyond 900 meters, up to a maximum altitude of 3000 meters. |
||||||||||||||||||||
Humidity | Operating:10% to 90% noncondensing short term -5° C to 55° C (23° F to 113° F) Nonoperating:Up to 93% noncondensing 35° C (95° F) maximum wet bulb |
||||||||||||||||||||
Altitude | Operating:Up to 3,000 m (9,840 ft.) Note: In China markets, regulations may limit installations to a maximum altitude of 2000 meters (6562 ft). Nonoperating:Up to 12,000 m (39,370 ft.) |
||||||||||||||||||||
Acoustic Noise Emissions | @100% PWM 8.8 Bels, @60% PWM 7.7 Bels | ||||||||||||||||||||
Vibration | Operating:0.15G (z-axis); 0.10G (X-, y-axes), 5-500Hz swept sine; IEC 60068-2-6 Test FC Nonoperating:0.5G (z-axis); 0.25G (x-, y-axes), 5-500Hz swept sine; IEC 60068-2-6 Test FC |
||||||||||||||||||||
Shock | Operating:3.5 G, 11 ms half-sine; IEC 60068-2-27 Test Ea Nonoperating:
|
||||||||||||||||||||
Regulations Meets or exceeds the following requirements: |
|||||||||||||||||||||
Safety | UL/CSA-60950-1, EN60950-1-2006, IEC60950-1 CB scheme with all country differences. | ||||||||||||||||||||
EMC | Emissions: FCC 47 CFR 15, ICES-003, EN55022, EN55032, KN32, EN61000-3-2 and EN61000-3-3. | ||||||||||||||||||||
Immunity | EN 55024, KN35 | ||||||||||||||||||||
Certifications |
|
||||||||||||||||||||
European Union Directives |
|
||||||||||||||||||||
Dimensions and Weight | |||||||||||||||||||||
Height | 42.6mm (1.7 in.) 1U | ||||||||||||||||||||
Width | 436.5mm (17.2 in.) | ||||||||||||||||||||
Depth | 737mm (29.0 in.) | ||||||||||||||||||||
Weight | Maximum:18.1kg (40 lbs.) fully populated. | ||||||||||||||||||||
Rack Mounting | |||||||||||||||||||||
Included Oracle Server X8-2 Rack Mount Kit |
|
||||||||||||||||||||
Service Clearance | Front: 123.2cm (48.5 in.) Rear: 91.4cm (36 in.) |